AC POWER SUPPLY
FREQUENCY CONVERTER / INVERTER



BL HP SERIES
High Power AC Power Supplies / Frequency Converters / Inverters without the High Price

High power Frequency Converter, AC power supply from 45Hz to 1000Hz

Behlman's high power, AC Power Sources / Frequency Converters / Inverters, combine the smooth, clean power of a linear supply with the compact design of a switching power supply. They're about one-third the size and half the cost of other AC Sources. All models come standard with variable voltage and frequency, external sync and 0-10 Vdc remote control, optional IEEE488 or RS232 interface for computer controlled. LabWindows and LabView  drives available. Small size, quiet operation and high efficiency make the high power BL Series ideal choices for precision avionics, ATE and industrial products testing requirements.


Features

  • Compact and rack mountable, 67% smaller than competitive units
  • Low cost per VA
  • Computer controlled waveform switching delivers smooth, efficient power
  • Multi-pulse input transformer offers low harmonic distortion
  • Available with an IEEE488/RS232 interface
  • LabWindows compatible
  • LabView compatible

Click here for printable Specifications Sheet.

Specifications

Input

Voltage: See Model Selection Guide
Frequency: 47-63Hz (Contact factory for additional frequency options)
Input Transformer: Multi-Pulse for low input current THD
Output
Voltage: See model information
Maximum Power: See model information
Current Crest Factor: 3:1
Distortion: 3% THD Typical
Efficiency: 80% Typical
Frequency: 45-500Hz (Optional 45-1000Hz)
Maximum Current: See model information
Regulation: ± 0.1% for ± 10% line change, ± 0.7% no load to full load

Protective Circuits

Input Protection: Fast acting main circuit breaker
Constant Current Mode: Overload automatically causes voltage foldback to provide maximum current without distorting output waveform
Thermal Protection: Internal temperature sensor prevent heat damage
Short Circuit Protection: Short circuit overload electronically latches output open to protect load. Power restored by cycling circuit breaker

Control Inputs

Voltage/Frequency: 0-10Vdc programming-voltage/frequency
External Synch: Synchronizes AC output with external input
Optional:

IEEE/RS232 interface for remote programming of output voltage and frequency

Front Panel Control

  • Power On/Off circuit breaker (C-5 requires contactor and fuses in place of circuit breakers)
  • Output On/Off toggle switch
  • Frequency and amplitude control (optional locking controls)
  • Digital readout (3.5 digits)-True RMS Voltage/true RMS Amps/Frequency
  • Phase select switch for multi-phase units
  • Line drop compensation
  • Fault Indicators
  • Phase Adjust

Mechanical & Environmental

Dimensions: See model information
Weight: See model information
Output Connections: Rear mounted barrier strip
Operating Temperature:

0 to 55 degrees C

Model Selection Guide

Model Optional Inputs

Config.: C-1 C-2 C-3 C-4 C-5 C-6 C-7 C-8 C-9 /C10 C-9A
Voltage: 120/208 220/380 277/480 200DELTA 346/600 230/400 240/415 115 /230 (2) 230/480 1phase (3) 230 1phase (4)
Output

Model

Power

Voltage Phase

Current 

Mech. Config.

BL3100(1)
  3KVA 0-135

1

  22.0 Amps

1

BL5100(1)
  5KVA 0-135

1

  37.0 Amps

2

BL7000(1)
  7KVA 0-135

1

  52.0 Amps

2

 
BL3200(1)   3KVA 0-270

1

  11.0 Amps

1

BL4500(1)   4.5KVA 0-270

1

  17.0 Amps

2

BL6000(1)   6KVA 0-270

1

  22.0 Amps

2

BL9200(1)   9KVA 0-270

1

  33.0 Amps

2

BL12000   12KVA 0-270

1

  44.0 Amps

3

 
BL3X350

  1KVA

0-135 3   2.6 Amps/ph

4

BL3300(1)
  3KVA 0-135

3

  7.5 Amps/ph

1

BL5000(1)
  5KVA 0-135

3

  12.5 Amps/ph

2

BL10000(1)
  10KVA 0-135

3

  25.0 Amps/ph

2

BL15000
  15KVA 0-135

3

  37.0 Amps/ph

3

BL20000
  20KVA 0-135

3

  50.0 Amps/ph

3

Mechanical Configurations:

1: 2-19" rack mounted chassis 7" & 3.5"Hx22"D, 150 lb.
2: 2-19" rack mounted chassis 7" & 8.75"Hx22"D, 250 lb.
3: High strength rack cabinet with casters 28.3"H x 31.6"D x 22.1"W, 425lb.
4: 1 – 19” rack mounted chassis 7” H X 22”D. 65 lbs. Available with C8 Input. 

Model Options
Options Description
CE CE Mark
E Extended frequency range, 45-1000 Hz.
L Locking pots
MA Mounting Angles (2 per chassis)
R Ruggedized for use in areas with shock and vibration.
MT Motor Test Option (Not available on 12000 and 20000)
S1 Slides for Mechanical Specifications 4
S3 Slides for mechanical configuration 1.
S10 Slides for mechanical configuration 2.
I / IR (I) IEEE-488 interface or (IR) RS232 interface
T1D 0-135 & 0-270 VAC L-N on BL3x350 (adds 3.5” chassis)
T3D 0-135 & 0-270Vac L-N on 3300, add 3.5"H chassis
T31D 0-135 & 0-270 VAC on BL3100 (adds 7” chassis)
T5 0-300Vac L-N on 5000, add 7"H chassis
T5D 0-135 & 0-300Vac L-N on 5000, add 7"H chassis
T51D 0-135 & 0-270 VAC on BL5100 (adds 7” chassis)
T10 0-300Vac L-N on 10000, add 7"H chassis
T10D 0-135 & 0-300Vac L-N on 10000, add 7"H chassis
T15 0-300 VAC L-N on BL15000
T20 0-300Vac L-N on 20000
T20D 0-135 & 0-300 VAC on BL20000
V Fixed output voltage (ie 115 )
F Fixed output frequency (ie 400)
21-00 Cabinet with casters

Note:

(1): Models with motor test option add -MT (See below).

(2): Single Phase, Not available on all models, consult factory.  

(3) C-9 & C-10 for Models BL4500, BL5000, BL5100, BL6000 & BL7000 includes option 21-00 cabinet See mechanical specification 3.  

(4) C9A for Models BL4500, BL5000 & BL5100 in the 8.75” chassis

Please note that Option MT includes all of the specifications of the standard BLHP Series plus the following to features to meet the requirements for motor testing:

  • Overload protection prevents output distortion to drive motors with pure sinewave, even during start up.
  • "Soft Start" allows starting motors in "locked rotor" condition by folding back the voltage and slowly increasing it as the motor starts to accelerate.
  • Capable of starting motors which normally require 140Amps locked rotor starting currents.

West Coast

2363 Teller Road / Suite 108,
Newbury Park, CA 91320
TEL (800) 456-2006 - (805) 375-7046
FAX (805) 498-2147

Headquarters:

80 Cabot Court.,
Hauppauge, NY 11788
TEL (800) 874-6727 - (631) 435-0410
FAX (631) 951-4341 * E-mail: sales@behlman.com

Easy Payment, We accept:
MasterCard, Visa, Discover,
American Express

About Behlman | Select a Product | Catalog Request | Support | GSA | Sales/Reps | Orbit Int'l | Home
AC Power Supply/Frequency Converter: SwitchingLinear | Inverters | UPS | Modified Standard Products
COTS: AC-DCDC-DC | Railroad Signal Source | New Products | Application Notes | Wild Frequency Information Center