AC POWER SUPPLY
FREQUENCY CONVERTER / INVERTER

BL-PLUS Series
THE WORLDWIDE CHOICE FOR QUALITY AC POWER

Behlman's BL-PLUS Series High Power AC Source/ Frequency Converter provides the performance of a linear with all the benefits of a switching amplifier. Instead of relying on large, noisy motor generators for AC power, today's testing facilities are switching to quiet, compact Behlman AC Power frequency converters.

Behlman's Solid-State BL-PLUS offers greater energy efficiency, reduced downtime, and a significantly smaller footprint. They're ideal for avionics, airborne and shipboard equipment as well as international products testing. The BL-PLUS even comes with an optional computer control for Automatic Test Equipment (ATE) application. It's adjustable voltage and frequency provides maximum flexibility. 

Combined with The efficiency of the BL-PLUS Series and the savings in converting from a motor generator really add up.

 

Features

  • Precise Adjustable Power: Variable amplitude & frequency with performance quality of a linear and the benefit of switching technology with option "M"

  • Small Footprint: 120KVA is only 27"Wx36"Dx78"H

  • Low Input Current Distortion: Multi-pulsed input transformer and soft start circuitry assures that it will not adversely affect other equipment on the power line

  • Line Drop Compensation for Remote Regulation

Specifications
Inputs
Transformer:
Multi-pulsed for low input current distortion
Voltage:
  • C1: 120/208 VAC

  • C3: 277/480 VAC

  • C4: 200 VAC DELTA

  • C5: 346/600 VAC

  • C2: 220/380 VAC

  • C6: 230/400 VAC

  • C7: 240/415 VAC

CX: Option voltages available
Frequency:

57- 63 Hz Standard

47 - 53 Hz Standard

Soft Start/Stop:
Ramped soft start circuitry eliminates turn-on surges. 
Input Service Requirements:
150% of System Rating
 

Output

Power:
See Model Selection Table
Voltage:

Fixed at any Line to Neutral Voltage

(-1)  0 - 132 Vac L-N, (-2) 0 - 264 Vac L-N, (-3) 0-305 Vac L-N.  

Additional output voltages available using transformers. 

Frequency:

Fixed at any frequency between 45 to 500Hz

Switch selectable, fixed frequency of 50, 60, and 400 Hz and variable range of 45 - 500 Hz with option "M" or "P"

Current:
See Model Selection Table
Power Factor:
100% of rated output into any power factor load.
Load Regulation:
+/- 0.7% No Load to Full Load.
Line Regulation:
+/- 0.5% for +/- 10% Line Change. 
Distortion:
3.0% typical THD 
Efficiency:
80% typical
 

Protective Circuits

Input Protection:
Electronic Circuit Breaker
Constant Current Mode:
Overload automatically causes voltage fold back to provide maximum current without distortion output waveform.
Short Circuit Protection:
Short circuit electronically latches output OPEN to protect load. Power restored by recycling Input Power.
Thermal Protection:
Internal temperature sensor prevents heat damage by turning output off…output will turn on when reaching safe temperature

 

Controls / Indicators

  • Push to Start

 

  • Push to Stop

  • Line Drop Compensation: Three recessed potentiometers for

          10% adjustment phase A, B, C

With Option "M"

  • Three (3) DMM's: VOLTS, AMPS, FREQ
  • Three position phase select switch: A,B,C
  • Three LED's: Constant Current, Overtemp, Overload Latch
  • Output: On/Off
  • Voltage Adjust Potentiometer. On adjustable models only.
  • Four position switch for frequency select of 50, 60, 400 Hz or Variable Frequency
  • Frequency Adjust Potentiometer. On adjustable models only.
  • Remote Control: 0-10 VDC for Voltage and Frequency, contact closure for Output ON/OFF

Mechanical Specifications

Dimensions:
  See Model Selection Table
Weight:
  See Model Selection Table
Operating Temperature:
  0 to 40 degrees Celsius
Storage Temperature:
  -20 to 70 degree Celsius
Humidity:
  0 - 95% RH non-condensing
Input Connections:

  Four (4) Pressure terminals; A, B, C, N. 

  Protective Ground Stud Provided

Output Connections:
  Four (4) Presure terminals; A, B, C, N
Remote Control:

  DB9M

Click on the Model Numbers for  Printable Specifications Sheets

 

Model Selection Guide

Models

Power
(KVA) 

No. of
Phases

Output (Volts)

Output (Amps)

Config.

Weight (lb.)

25

(-1) 0-132 V
190

1

900

25
1
(-2) 0-264 V
95
2
1200
BL+25-1 25 1 (-3) 0-305 V 82 2 1200
30
3
(-1) 0-132 V
76/phase
4
900
30
3
(-2) 0-264 V
38/phase

5

1200

30
3
(-3) 0-305 V
36/phase

5

1200

60
3
(-1) 0-132 V
152/phase
3
2000

60

3

(-2) 0-264 V
76/phase
3

2450

60

3

(-3) 0-305 V
66/phase
3

2450

120
3
(-1) 0-132 V
304/phase
3
2400

120

3

(-2) 0-264 V (For higher output voltage contact factory)
152/phase
3

2400

Configurations:

(1): 53"H x 31.6"D x 22.1"W, including forklift base.
(2): 63"H x 31.6"D x 22.1"W, including forklift base.
(3): 72"H x 36"D x 27"W, including forklift base.

(4): 49"H x 31.6"D x 22.1"W, including forklift base.

(5): 59"H x 31.6"D x 22.1"W, including forklift base.

Click Below -M for Manual  Controller Specifications Sheet

Click Below -P for Programmable Controller Specifications Sheet

Options

MAC2000 manual controller with three fixed frequencies of 50 Hz, 60 Hz and 400 Hz and variable frequency of 45-500 Hz
-P
PAC2000 programmable controller with 40 characters X 2 line Vacuum Fluorescent display and front panel pushbutton control or remote control using RS232 interface supplied with controller
-P3 Programmable Controller with independent Voltage adjust A, B, C with RS32 Interface
-PI
PAC2000 controller with IEEE-488 interface
-P3I Programmable Controller with independent Voltage adjust A, B, C with IEEE-488 Interface
-WF
“Wild Frequency” range of 350 to 880 Hz

 

Model Selection Guide

Model BL(+) [# of phases] - [Input] - [Output] -  [Options]

Examples

Model: BL+30-3-C2-1
Model: BL+30-3-C1-115-F400
Power: 30KVA unit, 3 phases output
Power: 30KVA unit, 3 phases output
Input: 220/380 VAC, 47-53Hz, 3 phases
Input: 120/208 VAC, 57-63Hz, 3 phases
Output: 0-132 VAC 

Output: 115/200 VAC with fixed freq (400 Hz). 

 

Notes: (Contact factory for the following options)

(1): Custom input and output.
(2): Higher output power configurations.
(3): Extended frequency.
(4): Dual output ranges.

 

West Coast

2363 Teller Road / Suite 108,
Newbury Park, CA 91320
TEL (800) 456-2006 - (805) 375-7046
FAX (805) 498-2147

Headquarters:

80 Cabot Court.,
Hauppauge, NY 11788
TEL (800) 874-6727 - (631) 435-0410
FAX (631) 951-4341 * E-mail: sales@behlman.com

Easy Payment, We accept:
MasterCard, Visa, Discover,
American Express

About Behlman | Select a Product | Catalog Request | Support | GSA | Sales/Reps | Orbit Int'l | Home
AC Power Supply/Frequency Converter: Switching | Inverters | UPS | Modified Standard Products
COTS: AC-DCDC-DC | Railroad Signal Source | New Products | Application Notes | Wild Frequency Information Center